Sondrestrom Lidar Operation Log


Operator(s) : E.Guðmundsson
Purpose : Routine Data Collection
Date(s) : 020201 - 020202
File(s) : L20020201_001 - L20020202_001
Comments :
Discovered a bug in the new program. When Restarting an experiment, the
program starts writing data to the first file in the experiment directory, regardless.

This means that there is a reckord at the end of the first file that stems from a
later time. A double increment fixed the problem. This will not be apparant in
the data transported over the transport network as the reckord are concateneted
in sequence of arrival. Will fix the bug!
Logfile : l0202010.log

Setup:0


Page : 961
[Variables]
Dye Power=75mJ
Rayleigh Power=490mJ

[0]
Iris=0.6mm
Rayleigh System=On
Dye System=On
Etalon=Out
Daystar=Out
Polarizer=In
HalfWave Plates=In
Rayleigh Filter=2:532(.5nm)
Rayleigh seeding=off

Logsheet:0


Page : 962

Sondrestrom Lidar Operation Log


Log Sheet 1 of 1
Operators : E.Guðmundsson
Date(s) : 020201 - 020202
File(s) : L20020201_001 - L20020202_001
FilesTime [UT]CommentsCntSOpe
L20020201_00121:46:18Start of experiment0EG
21:56:29Going to change chopper settings0EG
22:00:07Pushed chopper altitude up by 30uSec, incremented0EG
L20020201_00222:01:12running with a higher chopper setting now0EG
22:31:53The impossible happened, the new software crashed!0EG
recovered and incremented
L20020201_00222:32:370EG
00:51:05Haze present now0EG
L20020202_00001:25:00Verified convergence, could get no improvement0EG
L20020202_00103:32:52End of experiment0EG