Description


Page : 1077

Sondrestrom Lidar Operation Log


Operator(s) : E.Guðmundsson
Purpose : Routine data collection and tests
Date(s) : 021024 - 021025
File(s) : L20021024_000 - L20021025_001
Comments : New capacitor in the SP laser.

had difficulties converging at low altitues, but took an hours worth of data with the
best setting I could come up with. Investigated during the run the ocational
records
that are bad and there is indication that the chopeer is wearing out.
Logfile : l0210240.log

Setup:0


Page : 1078
[Variables]
Dye Power=75mJ
Rayleigh Power=480mJ

[0]
Iris=1mm
Rayleigh System=On
Dye System=On
Etalon=Out
Daystar=Out
Polarizer=In
HalfWave Plates=Tracking
Rayleigh Filter=2:532(.5nm)
Rayleigh seeding=off

Logsheet:0


Page : 1079

Sondrestrom Lidar Operation Log


Log Sheet 1 of 1
Operators : E.Guðmundsson
Date(s) : 021024 - 021025
File(s) : L20021024_000 - L20021025_001
FilesTime [UT]CommentsCntSOpe
L20021024_00021:35:09Start of experiment0EG
23:18:44tweeked sodium HG, it had drifted since start. energy0EG
now 65mJ
23:19:48have been taking data with chopper set at 30km0EG
23:20:17Changing chopper altitude to 70km....0EG
23:30:02Had some difficulties changing chopper alt. data in the 0EG
interim no good.
23:30:26taking data for an hour with the chopper set at 70km0EG
00:32:56Pausing rayleigh data aq to change convergence.0EG
L20021025_00101:11:48Resuming with convergence at a low altitude with0
max counts approximating what is normally at 25-30km
(normal data taking settings)
L20021025_00102:33:04End of experiment0