Description


Page : 1477

Sondrestrom Lidar Operation Log


Operator(s) : E.Guðmundsson
Purpose : IR data collection togeather with the Rayleigh 532nm channel
Date(s) : 040615 - 040616
File(s) : L20040615_000 - L20040616_000
Comments :
Logfile : l0406150.log

Setup:0


Page : 1478
[Variables]
Rayleigh Power=

[0]
front end Iris=not_installed
Rayleigh System=On
Rayleigh Field stop=2.0mm
Rayleigh path attenuation=0dB
Dye System=On
Sodium Field stop=0.5mm
Etalon=Out
Daystar=8A_In
Polarizer=In
HalfWave Plates=In
Rayleigh Filter=2:532(.5nm)
Rayleigh seeding=off

Logsheet:0


Page : 1479

Sondrestrom Lidar Operation Log


Log Sheet 1 of 4
Operators : E.Guðmundsson
Date(s) : 040615 - 040615
File(s) : L20040615_000 - L20040615_000
FilesTime [UT]CommentsCntSOpe
L20040615_00021:26:20Start of experiment0EG
L20040615_00021:31:30HV just turned on for the IR channel, taking some dark0EG
noise data as the radar is running.
L20040615_00021:34:32Going outside to open the shutter in front of theIR PMT0EG
L20040615_00021:41:42Just completed reconverging the IR, HV at 600V0EG
Dark counts ok, increasing HV to 625V
L20040615_00021:44:31HV now at 625V, dark counts still low at 30EG
L20040615_00021:45:12Increasingn to 650V0EG
L20040615_00021:46:39HV now at 650V. Reconverging for max altitude0EG
L20040615_00021:52:03Opening up the apperture a tad.0EG
L20040615_00021:54:21Doen opeing up the apperture, noise levels still ok,0EG
L20040615_00021:54:37opening up the apperture further0EG
L20040615_00021:56:17Done opeing more - background levels still ok at41 counts0EG
L20040615_00021:58:45Converged the IR again.0EG
L20040615_00022:00:40tryied converging again0EG
L20040615_00022:03:43Done converging, opening up the apperture further.0EG
L20040615_00022:05:31Done opening up the iris, looks like I may have over0EG
shot the mark, will have reduce the apperture again
L20040615_00022:06:27Turned down the HV instead to 600V, we can tolerate 0EG
upto 190counts per bin at 600V
L20040615_00022:27:20Converged the 532nm rayleigh channel0EG
L20040615_00022:47:18532nm: Changed HWP tracking to manual0EG
L20040615_00023:10:41disconnected convrging scope (IR)0EG
L20040615_00023:22:50just tweeked the Z axis of the Rayleigh channel0EG

Logsheet:1


Page : 1480

Sondrestrom Lidar Operation Log


Log Sheet 2 of 4
Operators : E.Guðmundsson
Date(s) : 040615 - 040616
File(s) : L20040615_000 - L20040615_001
FilesTime [UT]CommentsCntSOpe
L20040615_00023:27:15Reduced the apperture of the IR system due to clouds0EG
L20040615_00023:28:50Done reducing apperture, temporary - small patch of clouds0EG
L20040615_00023:29:41Turned HV off while waiting for clouds to pas by0EG
L20040615_00023:30:28done truning HV off0EG
L20040615_00023:31:28IR system now taking data with HV off0EG
L20040615_00023:40:32Turned HV on again (600V) on the IR , clouds passed by now.0EG
L20040615_00023:45:33Pushed teh chopper op a tad on the Rayleigh chanel0EG
L20040615_00023:49:32Opened the Rayleigh iris a tad0EG
L20040615_00023:50:46Clouds again in the path.0EG
L20040615_00100:11:32Changed Rayleigh daystar pod settign from 2.5 to 1.50EG
L20040615_00100:11:55Counts 850EG
L20040615_00100:13:10Counts 89890EG
L20040615_00100:13:23Counts 94940EG
L20040615_00100:15:42counts760EG
L20040615_00100:16:24counts810EG
L20040615_00100:17:27counts700EG
L20040615_00100:18:50counts670EG
L20040615_00100:18:57some clouds in the way.670EG
L20040615_00100:21:50counts700EG
L20040615_00100:21:57changing pod from 1.5 to 3.0700EG
L20040615_00100:23:33counts650EG
L20040615_00100:24:29counts680EG
L20040615_00100:25:28counts710EG
L20040615_00100:26:44counts770EG

Logsheet:2


Page : 1481

Sondrestrom Lidar Operation Log


Log Sheet 3 of 4
Operators : E.Guðmundsson
Date(s) : 040616 - 040616
File(s) : L20040615_001 - L20040615_001
FilesTime [UT]CommentsCntSOpe
L20040615_00100:27:33counts910EG
L20040615_00100:28:32counts930EG
L20040615_00100:29:29counts960EG
L20040615_00100:30:42pushed rayleigh chopper up by 20us980EG
L20040615_00100:31:44counts960EG
L20040615_00100:32:37counts0EG
L20040615_00100:32:43changing pod setting from 3.0 to 3.5950EG
L20040615_00100:33:43Done changing970EG
L20040615_00100:36:59counts1020EG
L20040615_00100:37:35counts930EG
L20040615_00100:38:54counts980EG
L20040615_00100:40:05counts990EG
L20040615_00100:44:06counts0EG
L20040615_00100:44:38Changing pod from 3.5 to 4.0980EG
L20040615_00100:45:58Done changing pod940EG
L20040615_00100:46:39counts930EG
L20040615_00100:47:36counts930EG
L20040615_00100:48:39counts800EG
L20040615_00100:49:37counts850EG
L20040615_00100:50:51counts780EG
L20040615_00100:51:42counts690EG
L20040615_00100:52:54counts750EG
L20040615_00100:53:01I may have passed the peek, turning pod back to 3.25750EG
L20040615_00100:54:25done changin pod700EG

Logsheet:3


Page : 1482

Sondrestrom Lidar Operation Log


Log Sheet 4 of 4
Operators : E.Guðmundsson
Date(s) : 040616 - 040616
File(s) : L20040615_001 - L20040616_000
FilesTime [UT]CommentsCntSOpe
L20040615_00100:54:42Counts650EG
L20040615_00100:55:46counts640EG
L20040615_00100:57:25Opening the apperture on the IR system a bit, maintaining0EG
600V Hv setting.
L20040615_00101:00:40counts970EG
L20040615_00101:07:04counts1050EG
L20040615_00101:46:05Have been trying to get a better convergence on the IR0EG
L20040615_00101:59:55this is the best I can do....Raddar collector current is990EG
modulating the DC level from the PMT! severe interferance!
L20040615_00102:07:39Background noise rising on IR channel, will have to stop down1000EG
L20040615_00102:09:33looking better now.1050EG
L20040615_00102:15:12Stopping furhter down0EG
L20040615_00102:24:36Noise problem gettign worse, closing shutter990EG
L20040615_00102:26:02Done closing shutter, the problem is not with the PMT.0EG
L20040616_00002:49:14taking down HV1070EG
L20040616_00003:00:55Problem found - the SRS preamp is working as a rectifyer 0EG
on the 1.29GHz sTX ignal introducing a significant DC level
on the output in the order of 100-200mV.
Turning RF off eliminates the problem (tested during a slew)
problem shows lot of varyability during slews.
L20040616_00003:26:23The telescope box will have to be screened. shutting down0EG
L20040616_00003:27:25End of experiment0EG