Description


Page : 1641

Sondrestrom Lidar Operation Log


Operator(s) : John Geiszler
Purpose : routine data collection
Date(s) : 050719 - 050720
File(s) : L20050719_002 - L20050720_004
Comments : Na Dye changed earlier today. Power now up to 85mJ
Logfile : l0507191.log

Setup:0


Page : 1642
[Variables]
Rayleigh Power=500mJ
Dye Power=85mJ

[0]
front end Iris=not_installed
Rayleigh System=On
Rayleigh Field stop=0.5mm
Rayleigh path attenuation=0dB
Dye System=On
Sodium Field stop=0.5mm
Etalon=Out
Daystar=8A_In
Polarizer=In
HalfWave Plates=Tracking
Rayleigh Filter=2:532(.5nm)
Rayleigh seeding=off

[1]
front end Iris=not_installed
Rayleigh System=On
Rayleigh Field stop=0.5mm
Rayleigh path attenuation=0dB
Dye System=On
Sodium Field stop=0.5mm
Etalon=Out
Daystar=Out
Polarizer=In
HalfWave Plates=Tracking
Rayleigh Filter=2:532(.5nm)
Rayleigh seeding=off

Logsheet:0


Page : 1643

Sondrestrom Lidar Operation Log


Log Sheet 1 of 1
Operators : John Geiszler
Date(s) : 050719 - 050720
File(s) : L20050719_002 - L20050720_004
FilesTime [UT]CommentsCntSOpe
21:14:54Start of experiment1100JDG
L20050719_00222:01:21counts1300JDG
L20050719_00222:21:35counts1340JDG
L20050719_00322:51:45GPIB error in Sodium channel, restarting experiment1250JDG
L20050719_00300:04:21counts1400JDG
L20050719_00301:02:11counts1380JDG
L20050719_00301:08:20 changed to setup 1 (etalon out)7260JDG
01:11:21chopper delay changed to set altitude to 35km0JDG
L20050719_00301:12:40counts3120JDG
L20050720_00101:54:35counts4950JDG
L20050720_00102:41:49counts6740JDG
L20050720_00303:55:02counts6160JDG
04:17:48error in rayleigh system, restarting data collection program0JDG
L20050720_00405:44:45counts1200JDG
L20050720_00405:56:12End of experiment-420JDG